Light and circuit breaker wiring:
This diagram shows Light and circuit breaker wiring. In this circuit, we use a DP MCB ( Double Pole Minature Circuit Breaker ), an RCCB ( Residual Current Circuit Breaker ), a Contactor, an RCBO ( Residual current operated Circuit Breaker with Overcurrent protection ), and a light. First, we need to connect, the DP MCB ( Double Pole Minature Circuit Breaker ), then connect the RCCB, then connect the Contactor, then connect RCBO with the contactor, then connect the lights.
Advertisements
Components needed For this Project:
You can get the components from any of the sites below:
- DP MCB 20A [See Buy Click Amazon]
- DP RCCB 16A [See Buy Click Amazon]
- Magnetic Contactor 25A [See Buy Click Amazon]
- SP RCBO 16A [See Buy Click Amazon]
- Spot Light 220V AC [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!
Advertisements
Components used to make the Light and circuit breaker wiring:
DP MCB In 2 Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls 2 Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control 2 Different Electrical Circuits at the same time, which allows the Appliances to Isolate safely and reliably. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches and Electrical components.
02. RCCB:
The Residual Current Circuit breaker RCCB is the Safest device to detect and Trip against Electrical Leakage current. This ensures protection against Electric shock Caused by indirect contact. Circuit breakers (CB) are automatically Operated Electrical Switches that Protect Electrical Circuits from Short-Circuiting or Overloading systems. It Protects against many major accidents. RCCB Circuit Breaker is an Electrical Wiring device whose function is to disconnect the current in the circuit.
A magnetic contactor is an electromagnetic switching device. It is generally used for controlling 3-phase Motors. The operation of a magnetic contactor is similar to that of a Relay. but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil. its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.
04. RCBO:
An RCBO protects Electrical equipment against 2 types of faults. Residual current and over current. Residual current. or earth leakage as it is sometimes referred to, occurs when there is a break in the circuit which can be caused by faulty electrical wiring or if the wire is accidentally cut. When there is a break in the circuit which may be due to faulty electrical wiring or accidental cutting of the wire. To prevent the current from being redirected and causing an electric shock. the RCBO current breaker stops it.
CFL stands for Compact Fluorescent Lamp which is an improved version of tube lights of earlier days. Like tube lights, it is a vacuum glass tube with fluorescent powder coating which is not as long and straight as tube lights but curved/twisted compact, or small in size. Like a tube light, it has electrodes or filaments at both ends. But in this case, instead of a choke, there is an electronic circuit that drives the Compact Fluorescent Lamp. Because the red wave is less in the light of the Tubelight and Compact Fluorescent Lamp, the object looks a little pale or the correct color of the object does not appear.
Thank You for visiting the website. Keep visiting for more Updates.
Frequently asked questions
Unlike power supply circuits diagram lighting circuits are always of the radial type. The cable leaves the consumer unit or runs to each outlet position before terminating at the last fitting on the line. Most houses have at least 2 lighting circuit diagrams- usually one upstairs and one down.
The white wire from the service panel was wired to one side of the light. The black wire was spliced to a black wire in a cable that runs to the switch. That cable's white wire was also connected to the switch and runs back to and is connected to the light.
In summary, a light circuit diagram works by allowing electricity to flow from a power supply source through wires into a light bulb, where the filament heats up and emits light. The switch was used to control the current flow of electricity to the light bulb, allowing the light to be turned on or off.
Light is a of electromagnetic radiation, which means it has electric fields or magnetic fields vibrating back and forth very quickly as a wave. Because of the strangeness of quantum mechanics, light is also made of little particles with no mass, called photons.
All photons travel at the speed of light. Considered among the subatomic particles, photons were bosons, having no electric charge, rest mass, and one unit of spin; they are field particles that are thought to be the carriers of the electromagnetic field.
Read more Single Phase Wiring
What is a kilowatt-hour (kWh) | kwh formula | What does kwh mean
Introduction to Electrical Units and CircuitskW and kWh on your electricity bill As your home uses electricity during...
What is the Difference Between kVA | What does KVA mean | kVA formula
Difference Between KVA ExplainedWhat does KVA Mean? There are technical terms aplenty when it comes to generators, and...
Power Factor | Power Unit | Energy | Electricity Unit
Power factor definition | Calculating Power FactorPower Factor Values In a purely resistive circuit, the power factor...