3-Phase Line Wiring Installation:

This diagram shows how to make 3 Phase Line Wiring Installation. In this circuit diagram, we use a single-phase energy meter, a neutral busbar, some single-phase circuit breakers, three RCBO Circuit Breakers, and an MCCB circuit Breaker. If you want to know more about this circuit diagram please check our youtube video for more details.

Advertisements

Diagram of 3 Phase Line Wiring Installation:

3 Phase Line Wiring Installation

Components needed For this Project:

You can get the components from any of the sites below:

  1.  SP MCB 10A [See Buy Click Amazon]
  2. Three Phase Energy Meter [See Buy Click Amazon]
  3. DP RCCB 32A [See Buy Click Amazon]
  4. TP MCB 32A [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Advertisements

Components used to make the (Project Name):

01. SP MCB:

In single-pole MCB, Switching and protection are Affected in only one Phase. Single phase supply to break the phase only. A single Pole breaker is Typically used with 120-volt Circuits, and a 6-20 amps Miniature Circuit Breaker. They are constructed with one Line Wire and one Neutral wire. A Single Pole switch is the most basic General-Purpose switch that you use to Control a light or another device from one location. These Switches have 2 Brass-Colored screw Terminals Connected to the hot Power source wires. Pole refers to the number of Circuits Controlled by the Switch SP Switches Control only one Switch Electrical Circuit.

02. 3-Phase Energy Meter:

The Meter Which is used for Measuring the Power of the 3-phase supply is known as the 3-phase energy meter. A 3-phase Energy meter is a 3-phase 4-wire direct Connected meter that is Used to estimate the electricity on the Three-phase power supply, mostly for residential & commercial use. A 3-phase meter helps consumers & utilities in revenue protection. The 3-phase meter is Constructed by Connecting the 2 single-phase meters through the shaft.

03. RCCB:

The Residual Current Circuit breaker RCCB is the Safest device to detect and Trip against Electrical Leakage current. This ensures protection against Electric shock Caused by indirect contact. Circuit breakers (CB) are automatically Operated Electrical Switches that Protect Electrical Circuits from Short-Circuiting or Overloading systems. It Protects against many major accidents. RCCB Circuit Breaker is an Electrical Wiring device whose function is to disconnect the current in the circuit.

04. TP MCB:

The full meaning of MCB is Miniature Circuit Breaker for TP MCB. MCB is an electromagnetic switch or device. If for any reason a short circuit occurs in the supply line or load line (line to line or line to neutral) or in case of overload MCB. the MCB automatically trips and disconnects the main line circuit or household power supply Connection. TP MCB In 3 Pole MCB, Switching & Protection is affected in only 3-Phases and the Neutral is not part of the MCB. 3 pole MCB signifies the Connection of Three Wires for a 3-Phase system Red-Yellow-Blue Phase. 3-Phase Supply Only Without Neutral.

TP MCB

Thank You for visiting the website. Keep visiting for more Updates.

Read more Single Phase Wiring