One Light One Switch Connection:

This diagram shows how to make one light one switch connection. In this circuit, we use an SP MCB ( Single Pole Miniature Circuit Breaker ), an ELCB ( Earth Leakage Circuit Breaker ), an SPST switch ( Single Pole Single Throw Switch ), and a light. First, we need to input a phase connection to SP MCB, then input a phase connection to ELCB from SP MCB, then input a neutral connection to ELCB, then need to connect the light, then need to connect the switch with the ELCB. Now this circuit is ready for use. If you want to know more about this circuit please check our youtube video below the post.

Diagram of One Light One Switch Connection:

One Light One Switch Connection

Components needed For this Project:

You can get the components from any of the sites below:

  1. SPST Switch [See Buy Click Amazon]
  2. ELCB [See Buy Click Amazon]
  3. SP MCB [See Buy Click Amazon]
  4. CFL Light [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Components used to make the One Light One Switch Connection:

01. SPST Switch:

An SPST (Single Pole Single Throw) Switch is a Switch That only Has a Single Input and can Connect Only to one Output. This means it Only Has one Input Terminal and Only one Output Terminal. A Switch is a Mechanical or Controlling Device That Changes the Flow of Current Direction or Interrupts the Flow of Current Within a Circuit. Single Pole Single Throws (SPST) is Perfect for on-off switching. When the SPST is closed, the Circuit is Closed and the light from the lamp switches on. When The Single Pole Single Throw (SPST) is then opened, the light from the lamp goes out and the Circuit is off.

02. ELCB:

ELCB complete earth leakage circuit breaker works on earth leakage production. Usually, the ELCB circuit breaker has two cables Phase and Neutral if any load is directly connected to the earth without taking neutral from ELCB then the circuit breaker will trip automatically. Earth leakage circuit breakers are used in applications to prevent electric shock and electrical fire caused by a short circuit or overload in the control panel by automatically closing when leakage is detected.

03. SP MCB:

In single-pole MCB, Switching & Protection is Affected in only one Phase. Single phase supply to break the phase only. A single Pole breaker is Typically used with 120-volt Circuits, 15-20 amps. They are constructed with one Hot Wire and one Neutral wire. An SP switch is the most basic General-Purpose switch that you use to Control a light or another device from one location. These Switches have two Brass-Colored screw Terminals Connected to the hot Power source wires. Pole refers to the number of Circuits Controlled by the Switch SP Switches Control only one Electrical Circuit.

04. CFL Light:

CFL stands for Compact Fluorescent Lamp which is an improved version of tube lights of earlier days. Like tube lights, it is a vacuum glass tube with fluorescent powder coating which is not as long and straight as tube lights but curved/twisted compact, or small in size. Like a tube light, it has electrodes or filaments at both ends. But in this case, instead of a choke, there is an electronic circuit that drives the Compact Fluorescent Lamp. Because the red wave is less in the light of the Tubelight and Compact Fluorescent Lamp, the object looks a little pale or the correct color of the object does not appear.