Start And Stop Wiring Diagram:

This diagram shows how to make a Start And Stop Wiring Diagram. In this circuit, we use a DP MCB ( Double Pole Minature Circuit Breaker ), a magnetic contactor, an SP MCB ( Single Pole Minature Circuit Breaker ), a start switch, and a stop switch. First, we need to connect the DP MCB with the power source, then connect the magnetic contactor with DP MCB, then connect the SP MCB with the contactor, then connect the start switch and stop switch. Now this circuit is ready for use.

Advertisements

Diagram of Start And Stop Wiring:

Start And Stop Wiring Diagram

Components needed For this Project:

You can get the components from any of the sites below:

  1. DP MCB 20A [See Buy Click Amazon]
  2. Magnetic Contactor 25A [See Buy Click Amazon]
  3. SP MCB 10A [See Buy Click Amazon]
  4. Push Button NO Switch [See Buy Click Amazon]
  5. Push Button NC Switch [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Advertisements

Components used to make the Start And Stop Wiring Diagram:

01. DP MCB:

DP MCB In 2 Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls 2 Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control 2 Different Electrical Circuits at the same time, which allows the Appliances to Isolate safely and reliably. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches and Electrical components.

02. Magnetic Contactor:

A magnetic contactor is an electromagnetic switching device. It is generally used for controlling 3-phase Motors. The operation of a magnetic contactor is similar to that of a Relay. but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil. its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.

03. SP MCB:

In single-pole MCB, Switching and protection are Affected in only one Phase. Single phase supply to break the phase only. A single Pole breaker is Typically used with 120-volt Circuits, and a 6-20 amps Miniature Circuit Breaker. They are constructed with one Line Wire and one Neutral wire. A Single Pole switch is the most basic General-Purpose switch that you use to Control a light or another device from one location. These Switches have 2 Brass-Colored screw Terminals Connected to the hot Power source wires. Pole refers to the number of Circuits Controlled by the Switch SP Switches Control only one Switch Electrical Circuit.

04. Start Switch:

NO (Normally Open) Terms Refer to a Type of Dry Contact or Wet Contact. A Push to Make Switch Allows Electricity to flow Between its 2 contacts when held in. When the button is released, the Circuit is broken. This type of Switch is also known as A Normally Open (NO) Switching system. As its name implies, a Normally Open (NO) Switch Contact or “a Contact” is a Switch. Put very simply, a Normally Open Sensor will have no Current When in a Normal State But When it Enters an Alarm State it will have +5V applied to the Circuit.

05. Stop Switch:

An NC (Normally Closed) Push Button is a Push Button That, In Its Default State, Makes Electrical Contact With The Circuit. An NC (Normally Closed) Push Button is a Push Button that, in its Default State, Makes electrical Contact With the Circuit. When The Button Is Pressed Down, The Switch no Longer Makes Electrical Contact And The Circuit is Now Open. When The Button is Not Pressed, Electricity Can Flow, But When it is Pressed The Circuit is Broken. This type Of Switch is Also known As a Normally Closed (NC) Switch.

Thank You for visiting the website. Keep visiting for more Updates.

Frequently asked questions

What is a start-stop switch?

Simple Explanation. A circuit diagram with a built-in single push button for turning on or off electrical devices, such as equipment or motors, is recognizable as a start-stop circuit. diagram In addition to overloads and contacts, these electrical circuit diagrams also include relays or contactors.

What is the wiring diagram?

Wiring diagram. A diagram that shows how a circuit diagram works logically and electrically. It uses symbols to identify components and interconnecting lines to display the electrical continuity of a circuit diagram. It is often used for troubleshooting purposes. Also known as a ladder circuit diagram.

What is the purpose of start and stop?

Quite simply, start-stop technology detects when your car comes to a halt and stops the engine automatically, then starts and engine again for you when you press the throttle.

What are the 3 types of wiring?

The 3 types of wires used in household circuits diagram are Earth wire, Live wire, and Neutral wire. Out of these Earth wire was used as a safety measure, especially for those appliances that have a metallic body. The color of insulation used for this wire was Green.

What is a 3-line electrical diagram?

What is a 3-line diagram? Also called a circuit diagram, it shows the connections to each component, and every circuit is shown. Also, every electrical component relevant to the system was drawn in this diagram. As a result, a complete three-line diagram can be used to create a bill of materials for the system.

Read more Single Phase Wiring