Automatic reverse forward motor control:
This diagram shows how to make automatic reverse forward motor control. In this circuit, we use 2 magnetic contactors and 3 timers. First, we need to input a phase line to connect all timers like in this diagram, then need to connect the magnetic contactor, and lastly, we need to input a neutral line to timers and contactors. Now it’s ready for use. If you want to know more about this circuit please check our youtube video below the post.
Advertisements
Components needed For this Project:
You can get the components from any of the sites below:
- Magnetic Contactor 40A [See Buy Click Amazon]
- 8 Pin Timer 220V AC [See Buy Click Amazon]
- SP MCB 10A [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!
Advertisements
Components used to make the Automatic reverse forward motor control:
A magnetic contactor is an electromagnetic switching device. It is generally used for controlling 3-phase Motors. The operation of a magnetic contactor is similar to that of a Relay. but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil. its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.
02. Timer:
A timer is a type of time-switching device that controls and controls Electrical circuits and electrical and electronic devices through time setting (on/off). The timer is basically 8-pin. Like other controlling devices the timer has a coil and when this coil is magnetized, the timer works on/off. The timer has 2 common ends and each common end has normally close and normally open options. When the timer is set by time, the timer trips at the end of that time and turns the common is normally closed (on) to open (off) and normally open (off) to close (on). This is how the timer works.
In single-pole MCB, Switching and protection are Affected in only one Phase. Single phase supply to break the phase only. A single Pole breaker is Typically used with 120-volt Circuits, and a 6-20 amps Miniature Circuit Breaker. They are constructed with one Line Wire and one Neutral wire. A Single Pole switch is the most basic General-Purpose switch that you use to Control a light or another device from one location. These Switches have 2 Brass-Colored screw Terminals Connected to the hot Power source wires. Pole refers to the number of Circuits Controlled by the Switch SP Switches Control only one Switch Electrical Circuit.
Thank You for visiting the website. Keep visiting for more Updates.
Frequently asked questions
Detailed Solution. The circuit diagram direction of rotation of a 3-phase induction motor can be reversed by interchanging any 2 of the three motor supply lines. Such that the field rotates counterclockwise rather than clockwise. However, the number Digite of poles and the speed at which the Project System magnetic field rotates remain unchanged.
Reversing the current direction of a motor can be performed on single and 3-phase motors, though shaded pole motors should and generally not be reversed. However, 1 should consider how, when, and why a motor must reverse directions and consider all of the power supply control problems of doing so.
Phase Reversal is when the phase sequence of a three-phase system is incorrect, and the connected three-phase motors and other rotating equipment run in the opposite direction. In many cases, this can cause a hazardous condition that may destroy products, damage machinery, and injure personnel.
Phase reversal occurs when a common-mode voltage, is outside of the specified and maximum range, and causes the input stage to interact with the Project System second stage causing an action that appears as if the current input pins were reversed. This is sometimes accompanied by and significant increase in input bias are current.
In some cases, phase reversal can cause damage to the motor, particularly if it is under load at the time of reversal. It can also lead to inefficient operation and potential safety hazards.
Read more Single Phase Wiring
What is a kilowatt-hour (kWh) | kwh formula | What does kwh mean
Introduction to Electrical Units and CircuitskW and kWh on your electricity bill As your home uses electricity during...
What is the Difference Between kVA | What does KVA mean | kVA formula
Difference Between KVA ExplainedWhat does KVA Mean? There are technical terms aplenty when it comes to generators, and...
Power Factor | Power Unit | Energy | Electricity Unit
Power factor definition | Calculating Power FactorPower Factor Values In a purely resistive circuit, the power factor...
0 Comments