What you can do to save electricity | Save electricity wiring:

This diagram shows how to make save electricity wiring. In this circuit diagram, we explain how can you save your electricity and how can improve the power factor in your house. In this circuit, we use a single-phase energy meter, a TP MCB ( Tripple Pole Miniature Circuit Breaker ), and four 400V 2.50uf capacitors. First, we need to connect the input power to the energy meter, then the input line to all capacitors like in our diagram, then input the power to TP MCB, and then input power to home loads from TP MCB. Now our circuit is ready for use. If you want to know more about this circuit please check our youtube video below the post.

Diagram of Save electricity wiring:

Save electricity wiring

Components needed For this Project:

You can get the components from any of the sites below:

  1. Single Phase Energy Meter [See Buy Click Amazon]
  2. TP MCB [See Buy Click Amazon]
  3. 2.50 MFD Capacitor [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Components used to make the Save electricity wiring:

01. Single Phase Energy Meter:

A Single-Phase Energy Meter is a sort of Watt-Hour meter. It consists of two Electromagnets. Single-Phase Energy Meter is also Popularly known as a watt-hour meter. One Magnet is called the shunt magnet Ml which is Mounted with a Pressure coil. The Pressure coil is a long coil Made of fine Copper wire which is connected across the Supply line. Single-phase energy meters are suitable for measuring single-phase AC current frequencies of 50/60 Hz, which are used for fixed indoor installations.

02. TP MCB:

The full meaning of MCB is Miniature Circuit Breaker. MCB is an electromagnetic switch or device. If for any reason a short circuit occurs in the supply line or load line (line to line or line to neutral) or in case of overload, the MCB automatically trips and disconnects the main line circuit or household power Connection. TP MCB In Three Pole MCB, Switching & Protection is affected in only Three-Phases and the Neutral is not part of the MCB. 3 pole MCB signifies the Connection of Three Wires for a Three-Phase system R-Y-B Phase. Three-Phase Supply Only Without Neutral.

03. 2.50 MFD Capacitor:

This 50 MFD Capacitor Electric motor Capacitor article Series Explains the Selection, Testing, installation, & use of Electric motor Starter Start and run Capacitors used on Various Electric Motors Found in or at Buildings such as air Conditioner Compressors, fan Motors, and some Good Pumps. An Electric motor’s run Capacitor (50 MFD Capacitor) Remains active after the Starting cap has Dropped from the circuit (as the motor has its proper speed), and 50 MFD Capacitor indeed the value of the run Capacitor can affect Motor Speed.

Watch to Youtube:

Thank You for visiting the website. Keep visiting for more Updates.

Read more Single Phase Wiring