Motor start with on delay timer:
This diagram shows how to make a motor start with on delay timer. In this circuit, we use 4 DP MCBs ( Double Pole Minature Circuit Breaker ), an RCCB ( Residual Current Circuit Breaker ), two magnetic contactors, an NC Switch, a NO Switch, and two single-phase motors. First, we need to connect the DP MCB with a power source, then connect the RCCB with the DP MCB, then connect the other DP MCB and contactors, then connect the single phase motor and push switch.
Components needed For this Project:
You can get the components from any of the sites below:
- DP MCB [See Buy Click Amazon]
- RCCB [See Buy Click Amazon]
- Magnetic Contactor [See Buy Click Amazon]
- NO Switch [See Buy Click Amazon]
- NC Switch [See Buy Click Amazon]
- 3 Phase Motor [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!
Components used to make the motor start with on delay timer:
DP MCB In Two Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls two Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control two Different Electrical Circuits at the same time, which allows the Appliances to Isolate in a safe and reliable manner. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches.
02. RCCB:
The Residual Current Circuit breaker RCCB is the Safest device to detect and Trip against Electrical Leakage current, thus Ensuring Protection against Electric shock Caused by indirect contact. Circuit breakers are automatically Operated Electrical Switches that Protect Electrical Circuits from Short-Circuiting or Overloading. It Protects against many major accidents. RCCB Circuit Breaker is an Electrical Wiring device whose function is to disconnect the current in the circuit.
A magnetic contactor is an electromagnetic switching device. It is generally used for controlling three-phase motors. The operation of a magnetic contactor is similar to that of a relay, but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil, its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.
04. NO Switch:
NO (Normally Open) Terms Refer to a Type of Dry Contact or Wet Contact. A ‘Push to Make’ Switch Allows Electricity to flow Between its two contacts when held in. When the button is released, the Circuit is broken. This type of Switch has also known as A Normally Open (NO) Switch. As its name implies, a Normally Open (NO) Switch Contact or “a Contact” is a Switch. Put very simply, a Normally Open Sensor will have no Current When in a Normal State But When it Enters an Alarm State it will have +5V applied to the Circuit.
An NC (Normally Closed) Push Button is a Push Button That, In Its Default State, Makes Electrical Contact With The Circuit. An NC (Normally Closed) Push Button is a Push Button that, in its Default State, Makes electrical Contact With the Circuit. When The Button Is Pressed Down, The Switch no Longer Makes Electrical Contact And The Circuit is Now Open. When The Button is Not Pressed, Electricity Can Flow, But When it is Pressed The Circuit is Broken. This type Of Switch is Also known As a Normally Closed (NC) Switch.
06. 3 Phase Motor:
A Three-Phase electric motor uses a 3-Phase Power Supply to Convert Electric Energy into Mechanical Energy. It contains four Wires (Three hot Wires and one Neutral Wire) and Uses 3 Alternating Currents of the Same Frequency. Since it Generates a Rotating Magnetic Field, it does not need a Capacitor for the Startup. Some Three-Phase Motors are Reversible, Which Means they can serve as Generators by Turning Mechanical Energy into Electrical Energy.
Thank You for visiting the website. Keep visiting for more Updates.
Read more Single Phase Wiring
3 Phase Motor Starter Wiring
3 Phase Motor Starter Wiring: This diagram shows how to make 3 Phase Motor Starter Wiring. In this circuit, we use a...
Start Button and Stop Button Wiring
Start Button and Stop Button Wiring: This diagram shows how to make Start Button and Stop Button Wiring. In this...
3 phase motor starter wiring
3 phase motor starter wiring: This diagram shows how to make Three phase motor starter wiring diagram. In this...
0 Comments