Single Phase Distribution Board Wiring:

This diagram shows how to make single-phase distribution board wiring. In this circuit, we use a single-phase energy meter, a DP MCB ( Double Pole Miniature Circuit Breaker ), an SPD ( Surge Protection Device ), an RCBO ( Residual current operated Circuit Breaker with Overcurrent protection ), three SP MCBs ( Single Pole Miniature circuit). This circuit diagram is very simple and easy to make. If you want to know more about this circuit please check our youtube video below the post.

Diagram of Single Phase Distribution Board Wiring:

Single Phase Distribution Board Wiring

Components needed For this Project:

You can get the components from any of the sites below:

  1. Single Phase Energy Meter [See Buy Click Amazon]
  2. DP MCB [See Buy Click Amazon]
  3. SPD [See Buy Click Amazon]
  4. RCBO [See Buy Click Amazon]
  5. SP MCB [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Components used to make the Single Phase Distribution Board Wiring:

01. Single Phase Energy Meter:

A Single-Phase Energy Meter is a sort of Watt-Hour meter. It consists of two Electromagnets. Single-Phase Energy Meter is also Popularly known as a watt-hour meter. One Magnet is called the shunt magnet Ml which is Mounted with a Pressure coil. The Pressure coil is a long coil Made of fine Copper wire which is connected across the Supply line. Single-phase energy meters are suitable for measuring single-phase AC current frequencies of 50/60 Hz, which are used for fixed indoor installations.

02. DP MCB:

DP MCB In Two Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls two Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control two Different Electrical Circuits at the same time, which allows the Appliances to Isolate in a safe and reliable manner. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches.

03. SPD:

The ability of an SPD to limit overvoltage in the electrical distribution network by diverting the surge current is the surge-protective component, the mechanical structure of the SPD, and the connection to the electrical distribution network. A surge protection device SPD is a component of an electrical installation protection system. This device is connected to the power supply in parallel with the load circuit it is intended to protect. It can be used at all levels of the Power Supply Network. It is widely used in overvoltage protection.

04. RCBO:

An RCBO protects electrical equipment against two types of faults; Residual current and over current. Residual current, or earth leakage as it is sometimes referred to, occurs when there is a break in the circuit which can be caused by faulty electrical wiring or if the wire is accidentally cut. When there is a break in the circuit which may be due to faulty electrical wiring or accidental cutting of the wire. To prevent the current from being redirected and causing an electric shock, the RCBO current breaker stops it.

05. SP MCB:

In single-pole MCB, Switching & Protection is Affected in only one Phase. Single phase supply to break the phase only. A single Pole breaker is Typically used with 120-volt Circuits, 15-20 amps. They are constructed with one Hot Wire and one Neutral wire. An SP switch is the most basic General-Purpose switch that you use to Control a light or another device from one location. These Switches have two Brass-Colored screw Terminals Connected to the hot Power source wires. Pole refers to the number of Circuits Controlled by the Switch SP Switches Control only one Electrical Circuit.

Thank You for visiting the website. Keep visiting for more Updates.