Timer switch with contactor:
This diagram shows how to make Timer switch with a contractor. In this circuit, we use a DP MCB (Double Pole Miniature Circuit Breaker ), an RCCB (Residual Current Circuit Breaker ), a magnetic contactor, a timer, and a transformer. First, we need to connect the DP MCB with the power source then connect the RCCB and contactor with DP MCB, then connect the transformer.
Advertisements
Components needed For this Project:
You can get the components from any of the sites below:
- DP MCB 25A [See Buy Click Amazon]
- DP RCCB 16A [See Buy Click Amazon]
- Magnetic Contactor 25A [See Buy Click Amazon]
- 8 Pin Timer 220V AC [See Buy Click Amazon]
- Transformer 12V [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!
Advertisements
Components used to make the Timer switch with contactor:
DP MCB In 2 Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls 2 Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control 2 Different Electrical Circuits at the same time, which allows the Appliances to Isolate safely and reliably. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches and Electrical components.
02. RCCB:
The Residual Current Circuit breaker RCCB is the Safest device to detect and Trip against Electrical Leakage current. This ensures protection against Electric shock Caused by indirect contact. Circuit breakers (CB) are automatically Operated Electrical Switches that Protect Electrical Circuits from Short-Circuiting or Overloading systems. It Protects against many major accidents. RCCB Circuit Breaker is an Electrical Wiring device whose function is to disconnect the current in the circuit.
A magnetic contactor is an electromagnetic switching device. It is generally used for controlling 3-phase Motors. The operation of a magnetic contactor is similar to that of a Relay. but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil. its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.
04. Timer:
A timer is a type of time-switching device that controls and controls Electrical circuits and electrical and electronic devices through time setting (on/off). The timer is basically 8-pin. Like other controlling devices the timer has a coil and when this coil is magnetized, the timer works on/off. The timer has 2 common ends and each common end has normally close and normally open options. When the timer is set by time, the timer trips at the end of that time and turns the common is normally closed (on) to open (off) and normally open (off) to close (on). This is how the timer works.
Using a transformer, electric energy can be moved from one AC circuit to another. A Transformer uses the electromagnetic induction principle to either increase or decrease the AC voltage (step-up or step-down). To lower the power in the circuits of low-voltage devices like doorbells, transformers are frequently utilized.
Thank You for visiting the website. Keep visiting for more Updates.
Frequently asked questions
the contactor was typically controlled by a circuit diagram that has a much lower power level than the switched circuit diagram, such as a (24-volt )coil electromagnet controlling a(230-volt) motor switch. Unlike general-purpose relays, contactors were designed to be directly connected to high-current diagram load devices.
The main timer switch function was to eliminate the need for leaving electrical circuit diagram diagrams or equipment running, thereby conserving energy and saving money. This ranges from having the device turn on at specific times to automatic shutoff.
The mechanical time switch was wired into a circuit diagram much like a small appliance circuit diagram, with an incoming electrical (LINE) cable connected to screw terminals on the switch, and the outgoing power supply cable connected to LOAD terminals.
Lighting timers can help you deter burglars and intruders by making your home look occupied, but they can also be vulnerable to tampering or hacking. To prevent this, you should secure your timer properly and avoid obviously patterns and clues.
Disadvantages of installing a digital timer switch include:
It needs a neutral wire, which is different from the ground wire. Using the ground wire, meanwhile, may cause danger. Digital timer switches also need different switchboards. Before the installation, you must plan.
Read more Single Phase Wiring
What is a kilowatt-hour (kWh) | kwh formula | What does kwh mean
Introduction to Electrical Units and CircuitskW and kWh on your electricity bill As your home uses electricity during...
What is the Difference Between kVA | What does KVA mean | kVA formula
Difference Between KVA ExplainedWhat does KVA Mean? There are technical terms aplenty when it comes to generators, and...
Power Factor | Power Unit | Energy | Electricity Unit
Power factor definition | Calculating Power FactorPower Factor Values In a purely resistive circuit, the power factor...
0 Comments