Creators
Rojony Khatun Author
Rojony Khatun
CalculatorToolsProjectExpert
Reviewers
Małgorzata Koperska, MD Steven Wooding
Last updated: October 4, 2025

Delta to Star Transformer Connection Diagram and Wiring Guide

🇺🇸
English
Default
🇪🇸
Español
Spanish
🇫🇷
Français
French
🇩🇪
Deutsch
German
Single phase 15 KVA Transformer

Single phase 15 KVA Transformer

single-phase 15 kVA transformer is an electrical device used to step up or step down voltage in three-phase power systems. Rated for 15 kVA, it is commonly used in industrial, commercial, and small utility applications to supply power efficiently while maintaining voltage stability and safety.

[single-phase-15-kva-transformer]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

delta to star Transformer Connection Diagram

Learn the Delta to Star transformer connection with primary delta, secondary star winding, neutral point, voltage ratios, and safe three-phase power distribution.

transformer primary secondary diagram

Delta to Star transformer is fed on delta and star on star. It offers a neutral point, balanced three-phase output, with mixed industrial and single-phase loads being the best.

electrical transformer wiring guide

Delta to star to transformer connection is a three-phase transformer connection used in the wiring of transformers where the primary winding is connected in the form of a delta and the secondary winding is connected in the form of a star (wye). This layout permits the secondary side to offer a neutral point in which single-phase loads may be connected, and offers phase-to-neutral voltage less than line voltage. The delta primary is efficient in passing the unbalanced load currents and minimizing the circulating third harmonics. In industrial plants, power distribution and supply of motor loads with both three-phase and single-phase requirements, delta-star transformers are extensively utilized. Proper wiring is important to maintain proper ratios of voltages, safe access to neutrals, balanced load sharing, and power arising. Testing includes testing of the primary delta connection, the secondary star with neutral, voltage levels, and phase sequence. Delta-star transformers are also used to step down the voltage to be distributed with three phases that remain stable.

Work & Installation (Input → Output Summary)

  • Primary Delta Winding connects three line phases forming a closed loop.
  • Secondary Star Winding connects three output terminals plus neutral.
  • Voltage Distribution: Line voltage appears on delta; phase-to-neutral voltage on star is line voltage ÷ √3.
  • Load Connection: Three-phase motors or single-phase devices connect to star terminals.
  • Phase Sequence: Check correct phase rotation to avoid motor/load issues.
  • Safety Devices: Fuses, breakers, and proper earthing for protection.
  • Proper wiring ensuresbalanced three-phase output, safe neutral access, and reliable voltage transformation.

Testing & Final Adjustments

  • Verify insulation and winding connections on both delta and star sides.
  • Measure primary line-to-line voltage and secondary line-to-neutral voltage.
  • Check phase sequence using a rotation meter.
  • Inspect connections for secure terminals and continuity.
  • Connect balanced loads gradually and monitor current distribution.
  • Confirm secondary neutral point is stable for single-phase loads.
  • Test overload protection devices for proper operation.
  • Ensure no excessive heating or vibration occurs under load.
  • Check repeated load conditions for stability.
  • Record voltage, current, and load readings for maintenance documentation.

Frequently Asked Questions - delta to star Transformer Connection Diagram:

What is a delta to star transformer connection?

Primary is delta connected, secondary is star connected with neutral for mixed loads.

Why use delta-star connection?

Provides neutral for single-phase loads, balances three-phase loads, and reduces harmonics.

Can it supply 3-phase motors?

Yes, with proper line connections and phase sequence verification.

What is the neutral used for?

To connect single-phase loads safely and provide stable phase-to-neutral voltage.

How to check phase sequence?

Use a phase rotation meter to ensure correct rotation and avoid motor issues.

Where is this connection used?

Industrial plants, mixed 3-phase and single-phase distribution, motor supplies.

What is the voltage ratio?

Secondary phase-to-neutral voltage is primary line voltage ÷ √3 for delta-star.

Is earthing necessary?

Yes, for safety of the neutral and transformer operation.

Can delta-star transformers step down voltage?

Yes, commonly used in distribution to reduce voltage levels safely.

Are protection devices needed?

Yes, fuses, breakers, and overload protection are essential.

Rojony Khatun

Rojony Khatun

Calculator Tools Project

Rojony Khatun is the creator of a free online tools website designed to simplify everyday and engineering-related calculations for students, professionals, and hobbyists. The platform offers a wide variety of basic and advanced calculators across key categories, including Electrical Calculators, Electronic Calculators, and Time & Date Calculators, helping users solve problems quickly and accurately.