Automatic water pump installation:

This diagram shows how to make an Automatic water pump installation. In this circuit, we use a DP MCB ( Double Pole Minature Circuit Breaker ), a Motor protector, a magnetic contactor, two float switches, and a 3-phase motor. First, we need to connect the DP MCB with the power source, then connect the motor protector with the DP MCB, then connect the magnetic contactor with the motor protector, then connect the float switch and the motor with the magnetic contactor. Now this circuit is ready for use.

Diagram of Automatic water pump installation:

Automatic water pump installation

Components needed For this Project:

You can get the components from any of the sites below:

  1. DP MCB [See Buy Click Amazon]
  2. Motor Protector [See Buy Click Amazon]
  3. Magnetic Contactor [See Buy Click Amazon]
  4. Float Switch [See Buy Click Amazon]
  5. 3 Phase Motor [See Buy Click Amazon]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Components used to make the Automatic water pump installation:

01. DP MCB:

DP MCB In Two Pole MCB, switching & protection is affected in phases and the neutral. A Double Pole or DP Switch is a Switch that Controls two Circuits at the same time. In terms of Residential Switching, this Normally means it Switches the live and Neutral at the same time. In Layperson Terms, Double Pole switches or DP Switches are Exclusively Designed to Control two Different Electrical Circuits at the same time, which allows the Appliances to Isolate in a safe and reliable manner. Fan or light Combinations and Medical Equipment are some of the many applications for DP Electrical Switches.

02. Magnetic Contactor:

A magnetic contactor is an electromagnetic switching device. It is generally used for controlling three-phase motors. The operation of a magnetic contactor is similar to that of a relay, but a relay is used for low-power or low-voltage connections, and a magnetic contactor is used for high-power or high-voltage connections. As soon as the supply is applied to the magnetic contactor coil, its normally open contacts are closed and normally closed contacts are opened and the associated devices are also operated. This is how a magnetic contactor works.

03. Motor Protector:

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

04. Float Switch:

A Float Switch is a type of Level Sensor Device Used to Detect the level of liquid within a tank. The Switch May be Used to Control a Pump, as an Alarm, as an Indicator, or to Control Other Devices. One type of Float Switch Uses a Mercury Switch Inside a Hinged float. Another common type is a Float Switch That Raises a rod to Actuate a Microswitch. One Pattern Uses a reed Switch Mounted in a Tube Float, Containing a Magnet, Surrounding the Tube, and Guided by it.

05. Single Phase Motor:

A Single-Phase Motor is an Electrically-Powered Rotary Machine That Can Turn Electric Energy into Mechanical Energy. It Works by Using a Single-Phase Power Supply. Single-phase Motors Are Used in Equipment And Machines That Are Smaller in Size And Require Lower Horsepower. This Includes Equipment Such As Refrigerators, Pumps, Compressors, Fans, and Portable Drills. Single-Phase Motors Have a Similar Construction to The Three-Phase Motor, Including an AC Winding That is Placed on The Stator And Short-Circuited Conductors That are Placed in a Cylindrical Rotor.

Thank You for visiting the website. Keep visiting for more Updates.

Read more Single Phase Wiring

0 Comments

Submit a Comment