Earth Bondhon
Creators
Md Jony Islam Author
Md Jony Islam
CalculatorToolsProjectExpert
Reviewers
Małgorzata Koperska, MD Steven Wooding
Last updated: September 27, 2025

3 Phase KVA to Amps Calculation Formula with Wiring Guide

🇺🇸
English
Default
🇪🇸
Español
Spanish
🇫🇷
Français
French
🇩🇪
Deutsch
German
3 phase 15 KVA Transformer

3 phase 15 KVA Transformer

A 3-phase 15 kVA transformer is an electrical device used to step up or step down voltage in three-phase power systems. Rated for 15 kVA, it is commonly used in industrial, commercial, and small utility applications to supply power efficiently while maintaining voltage stability and safety.

[3-phase-15-kva-transformer]

*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

3 Phase KVA to Amps Calculation Formula Wiring

Learn how to calculate 3-phase KVA to Amps using a formula with wiring guide, examples, and protection tips for motors, transformers, and distribution panels.

kVA to amps conversion 3 phase:

The The KVA to Amps formula is used to determine current using apparent power and voltage in the 3-phase. It finds extensive applications in transformer, motor, and generator wiring design.

3 phase transformer kVA to amps:

The 3-phase KVA to Amps calculation is essential for selecting proper cables, breakers, and protective devices in electrical systems. The formula is:

\[ I (A) = \frac{1000 \times KVA}{\sqrt{3} \times V} \]

Where: I is current in Amps, kVA is apparent power, and V is line to line voltage. E.g., a 50 kVA load at 415 V will require approximately 70A. This formula is extensively applied when it comes to the calculation of the load current of motors, generators, and transformers. The calculated current in the wiring is needed to determine the appropriate conductor size, MCCB/MCB rating, and relay settings. This is supplied by a 3-phase supply and through protective devices to the output load. Grounding and balancing phases properly are essential in order to have safe working conditions. A clamp meter tests the actual current with computed values. The approach keeps the equipment efficient, safe, and long-lived.

⚡ Work & Installation (Input → Output):

This 3-phase source of power is used to start the installation, with the voltage applied to a load, which could be a motor, a transformer, or a distribution panel. Primary, the load KVA rating is applied in combination with the supply voltage to estimate the anticipated current with the help of the KVA to Amps formula. Cables, circuit breakers, and protective relays are chosen for this current. All the input supply is passed by MCCB/MCB or protective relay, and then to the load. As an illustration, a 415 V- 100 kVA transformer is approximately 139A, thus cables and breakers are of that capacity. The wiring is done in such a way as to have a balanced distribution of current in all three phases. Lastly, the result is a constant supply to the load, and overload protection and adequate grounding are provided to ensure safety.

Testing & Final Adjustments:

Testing is done after installation so that the wiring and protection can be made equivalent to the calculated current. Test every connection with insulation resistance: First. Turn the power on and apply a load current on every phase with a clamp meter. Compare measured with calculated amps of the KVA formula. When the circuit is unbalanced, rearrange the circuits to obtain a phase balance. Will change MCCB/MCB or relay settings depending on the full load current. Check grounding; also, make sure that cable temperatures are safe when loaded. In case there are motors in the system, ensure that the starting current is not above the protective device ratings. Such modifications will ensure that 3-phase wiring will operate safely over the long run.

Frequently Asked Questions - 3 Phase KVA to Amps Calculation Formula Wiring:

What is the 3 phase KVA to Amps formula?

I = (1000 × kVA) / (√3 × V).

Why use √3 in 3 phase calculation?

Because line-to-line voltage is √3 times the phase voltage.

How many amps is 50 kVA at 415V?

About 70 Amps.

How many amps is 100 kVA at 415V?

About 139 Amps.

Is the formula different for single phase?

Yes, it is I = (1000 × kVA) / V without √3.

Where is KVA to Amps calculation used?

It is used in transformer, generator, and motor sizing.

How do I choose cable size from KVA?

First calculate Amps from KVA, then select cable based on ampacity.

Can unbalanced loads affect calculation?

Yes, loads should be balanced across three phases for accuracy.

What protection devices are used?

MCB, MCCB, relays, and fuses sized to the calculated current.

Why calculate amps from KVA?

It ensures safe selection of conductors and protective devices.

Md Jony Islam

Md Jony Islam

CalculatorToolsProject

Founder of Earthbondhon.com

a free online tools website designed to make everyday and engineering-related calculations easier for students, professionals, and hobbyists. The site offers a wide range of basic calculators across key categories, including Electrical Calculators, Electronic Calculators, and Time & Date Calculators.